China factory absolutely sealed laboratory high pressure
chemical reactor autoclave
Model | weight: normal; font-size: 12px;">CJF-0.05L | CJF-0.1L | CJF-0.25L | CJF-0.5L | CJF-1L | CJF-2L | CJF-3L |
Kettle volume | 50ml | 100ml | 250ml | 500ml | 1000ml | 2000ml | 3000ml |
design pressure | not more than 22mpa |
set tempreture | not more than 300℃ |
heating method | Conventional electric heating, far infrared, heat transfer oil, steam, circulating water, etc. |
heating power | 0.9KW | 1.5KW | 2KW | 2.5KW |
Stirring speed | Startup ~ 800 rpm (stepless speed regulation) |
Lined | Can be made of polytetrafluoroethylene lining (safety temperature 180 degrees), glass lining, etc. (this option) |
Temperature controller | Self-adjusting function intelligent digital control meter with automatic constant temperature control function, with speed display and stepless speed adjustment function, equipped with heating voltmeter, working schedule. |
Temperature controller working environment | Ambient temperature: 0 ~ 50 ℃, relative humidity: 30 ~ 85%, no conductive dust, no Egyptian corrosive gas in the surrounding medium |
Remark | Can be customized according to customer requirements |

Precautions: 1. The autoclave is a precision device. The sealing ring adopts a conical surface contact sealing form. By tightening the main bolts, they are pressed against each other to achieve the purpose of sealing. Special care must be taken to seal the cone surface to avoid various collisions and damage to it. When installing the lid, first place the reactor kettle body, and then place the kettle lid in the fixed position and carefully install it on the kettle body. When tightening the main bolt, you must tighten it diagonally and symmetrically for several times. Uniform, do not allow the kettle lid to tilt to one side to achieve a good sealing effect. Do not exceed the specified tightening torque to prevent the sealing surface from being crushed or accelerated. 2. After each operation, the residue on the kettle body and kettle lid should be removed. All sealing surfaces on the autoclave should be cleaned frequently and kept dry. It is not allowed to use hard or rough surfaces for cleaning. 3. The reactor should be used and operated strictly in accordance with the "Safety Procedures for High Temperature and High Pressure Reactors". It should not be operated alone, and more than two people are required for the experiment. 4. During the work of the autoclave, open the ventilation fan to ensure good ventilation. 5. When there is pressure in the kettle, it is strictly forbidden to twist the nut or knock on the autoclave. 6. At the connection of the positive and negative nuts (inlet pipe, exhaust pipe, and branch pipe connecting the pressure gauge and the kettle cover), only rotate the nut, and do not allow the two sealing surfaces to rotate relatively. 7. Observe the indication of the pressure gauge at any time during operation. It is strictly forbidden to use the kettle under the conditions of overtemperature and overpressure. 8. If there is air leakage during the experiment, stop heating immediately and stop the experiment. It is strictly forbidden to twist the nut at high temperature.

Over the past 20 years, we have gained the trust and support of many customers. Our company has established close cooperative relations with many world famous brands, providing high-quality products and pre-sales and after-sales services for the scientific research and development of all walks of life. In order to respond to the national "ribbon" strategy, we set up an overseas international business department to become a cross-border e-commerce to expand overseas markets and bring high-quality products to overseas customers.

1.Do you provide free samples? A:Yes. We offer free samples, including customized samples. You only need to pay the freight. Sample delivery date is within 1- 3days, customized sample is about 3-7days. 2.Can you provide us a competitive price and good quality products? A:Yes. We have our strict evaluation criteria of quality on our partner factory, and we did complete and detailed market research and priced competitively. 3.What is your terms of payment? A:We accept T/T, Visa, MasterCard, E-checking, L/C, Western Union and more.Please choose your preferred payment method. 4.How to inspect the goods? A:Products will be checked by our QC staff first , then our project manager. Client can come and check by themselves or third-party check is available.
Contact us if you need more details on reactor high pressure. We are ready to answer your questions on packaging, logistics, certification or any other aspects about
high pressure reactor autoclave、laboratory high pressure chemical reactor. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Lab equipment > high pressure reactor